Product Standard
Enterprise Standard
Application
HO5VVC4V5-K Wind power oil resistant shielded control cable is applicable for free hanging or fixed installation in fin cabin.
Environment Conditions
Ambient air temperature: Perennial mean temperature: 10℃
Extreme high temperature: 50℃
Extreme low temperature: -42℃
Average relative humidity: normal value for accumulated year: 80%
Earthquake Proof: Horizontal acceleration: 0.2g
Normal acceleration: 0.1g
Safety factor: 1.67
Note: g is acceleration of gravity. g=9.8m/s²
Extreme wind speed: 30.0m/s
Range of Laying
Cables mainly lay in the cabin of fan, where machinery oil may leak or overflow.
Operating Properties
Rated Voltage U0/U: 300/500V
Continues operating temperature:
Flexible: -5~+70℃
Fixed: -40~+70℃
Min. ambient temperature when laying: -5℃
Min. bending radius :
Flexible:10d
Fixed:5d
d: outer diameter
Introduction
Conductor
Conductor should comply with the requirements for Class 5 specified in IEC60228.
The surface of conductor should be bright and clean no grease, no burr or bulge or faulted wire to damage the insulation.
Isolated layer
Every conductor coat with an isolated layer made from appropriated material.
Insulation
The nominal value of the insulation thickness complies with DIN VDE 0281-13. The average value of insulation thickness should be no less than nominal value, and the thinnest part should be no less than 90% -1mm of nominal value.
Insulation adopts PVC, whose property should comply with provisions FOR TI2 in DIN VDE 0281. The insulation should be rapped on conductor tightly and easy to peel without damaging the insulation, conductor and coating. The surface of the insulation should be flat and color evenly.
Insulated conductors are separated by figures, and in accordance with DIN VDE 0293. Generally, yellow-green ground wire should be the outermost part of the core. (For three cores and above)
Inner Sheath
The nominal value for thickness of inner sheath should comply with DIN VDE 0281-13. Meanwhile, the average value of should be no less than nominal value while the thinnest part should be no less than 85%-0.1mm of the nominal value.
Sheath is made from oil-resist soft PVC, whose properties should comply with requirements for TM2 specified in DIN VDE 0281 T1. The sheath should tightly rapped on stranded insulated core or coating. Meanwhile, the outer sheath should be clean and color evenly.
Shield
The shield layer adopts tinned copper braid with density no less than 85%.
Sheath
The nominal value for thickness of inner sheath should comply with DIN VDE 0281-13. Meanwhile, the average value of should be no less than nominal value while the thinnest part should be no less than 85%-0.1mm of the nominal value.
Sheath is made from oil-resist soft PVC, whose properties should comply with requirements for TM2 specified in DIN VDE 0281 T1. The sheath should tightly rapped on stranded insulated core or coating. Meanwhile, the outer sheath should be clean and color evenly.
The outer diameter should comply with requirement in DIN VDE 0281-13. The color for sheath is grey or black.
Finished Cables
The ohmic value of conductor should be no more than specifications in IEC60228 at 20℃.
Finished cables and insulated cores should withstand the rated AC voltage test of 2500V, and no breakdown in five minutes.
The resistance of insulated conductor should be no more than 20MΩ•km.
Mechanical and physical properties for finished cable insulation should comply with DIN VDE 0282-4.
Mechanical and physical properties for finished cable sheath should comply with DIN VDE 0282-4.
Finished cables should withstand the burning test specified in EN50265-2-1 or IEC60332-1.
Finished cables should withstand the oil-resist test specified in DIN VDE 0473 6081-2-1.
Inspection Rules
Products can leave factory only after passing examination of technology department. Each package should be shipped with the product quality inspection certificate.
Products should inspect according to DIN VDE 0281-13. If it fails for the first time in sample inspection, then take another two samples to examine the failed project. If the two samples are acceptable, then the products are acceptable, false otherwise. The number of samples is accepted by both sides, or decided by manufacture at the time of no requirements from the buyer.
Mark、Packing、Transport and Storage
Mark
There should be marks of maker, type, nominal cross-section area, voltage on the cable. The marks should comply with the requirements for conductor and color specified in DIN VDE 0293-308.
Marks shall be legible, not easy to erase. The writing should be clearly visible after 10 times graze in absorbent cotton cloth.
Packing
Cables can be packed both in coils and in circles. Cables in circle should be packed on cable specified in JB/T8137. Cables should be positive sealing, for those outside the circle, protective cover should be made. And the length of outside should be no more than 300mm.
Tags should identify:
① Maker or trade-mark
② Type and specifications mm²,V
③ Lengths m
④ Manufacturing Date: Year Month
⑤ Product Standard Code
⑥ Correct direction for circles
Transport and Storage
The cables should avoid high temperature and cable circle does not allow flat.
Forbid throwing circles with cable from high attitude and mechanical damage.
Forbid lifting several circles at the same time. Circles should be put firm with appropriate methods to avoid tip over.
![]() |